BioLogic Potentiostat SP-150

Full featured economical research grade potentiostat, can be customized to address all applications in the area of classical electrochemistry.

  • Current range: 10 μA to 800 mA

  • Current resolution: 760 pA

  • Control voltage: ±10 V

  • Compliance: 20 V range adjustable [-20;0:20]

  • Voltage resolution: 5 μV

  • EIS measurement from 10 µHz to 1 MHz

CO2 Universal Laser & Engraver

VLS 3.60 with 30 watt, 10.6 µm Co2 Laser Source

  • Laser Processing area: 609.6 X304.8 mm

  • Laser max power: 30 Watt

  • Engraving and Cutting operations are available

  • Available Focus Lenses: Standard 2.0 & HPDFO Lens

Biolin Scientific Theta Lite - Optical Tensiometer

Static and Dynamic contact angle measurement

  • Number of Dispensers: 2

  • 1280 x 1024 px Camera

  • Max FPS : 2068

  • Manual droplet Placement

  • Manual YZ Sample Stage

  • Frame intervals range: 0.33 ms to 1000 s

Profilm3D: Optical Profilometer

Profilm3D uses state-of-the-art white light interferometry (WLI) to measure surface profiles and roughness.

  • Z Range: 100 mm

  • XY Stage Range: 100 mm x 100 mm

  • Camera: 2592 x 1944 (5 megapixels)

  • Piezo Range: 500μm

  • Thickness Range, WLI: 50 nm - 10 mm

Leica DM 2000 LED (Fluorescence Microscope)

Upright light microscope with additional fluorescence module.

  • 4x, 10x, 40x, 100x HI Plan Objectives, 10x eye pieces

  • 2.5 MP CMOS Sensor Camera, C-mount adapter

  • LAS 4.50 Extended Annotation Software

  • 30-Watt Illumination

Voltera V-one PCB Printer

Equipment capable of printing 2 sided PCBs

  • Print area: 128 x 105mm

  • 0.2 mm of minimum trace width

  • Spindle Speed: 13,000 RPM

  • Drill Bits: 0.07 to 1.60mm

  • Bed Temperature: 240℃

  • File Type: Gerber, USB Connectivity

OrigaFlex - OGF500 For EC Measurement

OGF500 pack is a potetiostat & glvanostat for electrochemical measurment with maximum current of 500 mA.

  • Current ranges: ±5 nA to ­±500 mA

  • Current resolution: 0.003 % (±150 fA)

  • Applied potential: ±15 V

  • Compliance Voltage: ±20 V

Holmarc Direct UV Laser Writer for Photolithography

4" substrate direct UV laser writer for mask less lithography.

  • GaN laser diode, Wavelength: 405nm

  • Spot size : 1 micron

  • Resolution: 1 micron

  • Maximum Intensity: 3 mW

  • Z-axis travel: 20mm

  • X and Y axis travel: 100mm

Flashforge Creator Pro – FDM 3D Printer

FDM based 3D printing up to 100µm accuracy with PLA, ABS and PCL Materials.

  • Dimensions: 227L x 148W x 150H mm

  • Nozzle Diameter: 0.4 mm

  • Layer resolution: 100 – 500 microns

  • Communication: USB, SD Card

  • Positioning Precision: 2.5 µm (z-axis)

  • Filament Diameter: 1.75 mm

Apex spinNXG-P1A Spin Coater

Primarily for deposition of thin coatings of liquid on the different substrates (glass, PCB, Si Wafer).

  • 100 – 10000 Rotations per minute

  • 15 programs preset editable programs, 20 steps with 1-9999 seconds gap per step

  • Chuck Sizes Available: 25 & 75 mm

  • PC & Keypad Control

Wanhao Duplicator 7 (D7) Resin Based 3D Printer

The Wanhao Duplicator 7 DLP uses the vat photopolymerisation 3D printing technology which is faster than SLA 3D Printing.

  • Technology: DLP (Digital Light Processing)

  • Build Volume: 120 x 68 x 180mm

  • Layer Resolution: 35 microns

  • Connectivity: USB

  • Printable materials: 405 nm UV resin

Z-Morph Multi-tool CNC & 3D printer

Multipurpose tool with interchangeable tool heads capable of of FDM 3D printing (50 µm accuracy), CNC cutting/drilling and PCB Engraving.

  • Work Area: 250 x 235 x 165 mm

  • Nozzle Diameter: 0.4, 0.2 mm

  • Layer resolution: 50 – 400 µm

  • Communication: USB, SD Card

  • Mechanical Precision : 0.6 µm for z-axis

Ossila's Four-Point Probe System (Ω, ρ, κ Measurement)

Ossila's Four-Point Probe System is an easy-to-use tool for the rapid measurement of sheet resistance, resistivity, and conductivity of materials.

  • Voltage range: ±100 μV to ±10 V

  • Current range: ±1 μA to ±150 mA

  • Sheet resistance range: 3 to 10 (ohms per square)

  • Measurement accuracy: < ±4%

  • Measurement precision: ±0.5%

Holmarc Syringe/Infusion Pumps

A pair of Holmarc Syringe/Infusion pumps with controllers are used for our various microfluidics applicaitons involving precision controlled circulation like droplet microfluidics, particle encapsulation, etc.

  • Model: HO-SPLF-01

  • Compatible Syringes: 5ml to 60 ml (Standard Off the shelf syringes)

  • Flow Rates: 15.63 μl/hr to 36.2 ml/min (Dependent on syringe size & Manufacturer)

  • Dispensing accuracy of +/- 1 %

  • Control: On-board controller or PC (via RS-232 interface)

Labman LMDV-60 Rotational Viscometer

FDM based 3D printing up to 100µm accuracy with PLA, ABS and PCL Materials.

  • Range: 20-2,00,000 cP

  • Small sample adapter volume: ~ 5 ml

  • Display for Results and Temperature

  • With Low viscosity adapter (0.1 -20 cP)

  • Number of spindles: 4

Photolithography Setup

  • Mega A3 Laminator

    • Max width 325 mm

    • Maximum Substrate Thickness: 3mm

  • Mega Electronics AY315 UV Expoure Unit

    • 6 x 15W UV Tubes

    • Working Area: 260 x 355 mm

    • Vacuum Supported